The 115-volt version of our popular gear transfer pump is the M-1115S. Designed for stationary locations, the M-1115S offers a 30-minute duty cycle from a permanent magnet motor. Reliability and ease of maintenance are the hallmarks of this versatile fuel transfer pump.
Specifications | M-1115S-MU | M-1115S-AU |
---|---|---|
Design Type | Gear | Gear |
Voltage | 115 Volts AC | 115 Volts AC |
Flowrate | Up to 12 GPM - Up to 45 LPM | Up to 12 GPM - Up to 45 LPM |
Nozzle | Manual | Automatic |
Mechanical Connection | 1 in. Inlet - 3/4 in. Outlet | 1 in. Inlet - 3/4 in. Outlet |
Duty Cycle | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off |
Power Cord | None | None |
Hose | 12 ft - 3.7 m - 3/4 in. diameter | 12 ft - 3.7 m - 3/4 in. diameter |
Motor Protection | Internal auxiliary temperature-limiting device & circuit breaker | Internal auxiliary temperature-limiting device & circuit breaker |
Suction Pipe | Adjustable 40 in. | Adjustable 40 in. |
To Use With | Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene | Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene |
Unique Features | Designed for stationary locations in fleet, agriculture or light industrial applications. | Designed for stationary locations in fleet, agriculture or light industrial applications. |
Approvals | U. L. Listed, CSA Certified | U. L. Listed, CSA Certified |
Warranty | 2 years | 2 years |
This transfer pump is built with a 1/3 horsepower motor and designed for high performance. The M-3120 is the 115-volt transfer pump of choice for heavy equipment applications.
Specifications | M-3120-ML | M-3120-AL | M-3120-PO | M-3120-B100-ML | M-3120-B100-AL | M-3120-AD |
---|---|---|---|---|---|---|
Design Type | Vane | Vane | Vane | Vane | Vane | Vane |
Voltage | 115 Volts AC | 115 Volts AC | 115 Volts AC | 115 Volts AC | 115 Volts AC | 115 Volts AC |
Mechanical Connection | 1 in. Inlet 3/4 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet |
Reads | Gallons - Litres | Gallons - Litres | Gallons - Litres | Gallons - Litres | Gallons - Litres | Gallons - Litres |
Flowrate | Up to 20 GPM - Up to 75 LPM | Up to 20 GPM - Up to 75 LPM | Up to 20 GPM - Up to 75 LPM | Up to 20 GPM - Up to 75 LPM | Up to 20 GPM - Up to 75 LPM | Up to 20 GPM - Up to 75 LPM |
Nozzle | Manual | Automatic | Pump Only | Manual | Automatic | Automatic |
Duty Cycle | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off |
Power Cord | Sold Seperately | Sold Seperately | Sold Seperately | Sold Seperately | Sold Seperately | Sold Seperately |
Hose | 12 ft 3.7 m 3/4 in. diameter | 12 ft 3.7 m 3/4 in. diameter | 12 ft 3.7 m 3/4 in. diameter | 12 ft 3.7 m 3/4 in. diameter | 12 ft 3.7 m 3/4 in. diameter | 12 ft 3.7 m 1 in. diameter |
Motor Protection | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device |
Suction Pipe | None | None | None | None | None | None |
To Use With | Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene | Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene | Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene | Biodiesel (B100), Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene | Biodiesel (B100), Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene | Diesel fuel, Up to 20% biodiesel blends such as B20, Gasoline, Up to 15% alcohol blends such as E15, Kerosene |
Unique Features | External switch coverplate allows for easy access and keeps the UL rating intact | External switch coverplate allows for easy access and keeps the UL rating intact | External switch coverplate allows for easy access and keeps the UL rating intact | B100 Fuel requires a minimum operating temperature of 40 degrees Farenheit | B100 Fuel requires a minimum operating temperature of 40 degrees Farenheit | External switch coverplate allows for easy access and keeps the UL rating intact. |
Approvals | U.L. Listed to U.S. and Canadian Standards | U.L. Listed to U.S. and Canadian Standards | U.L. Listed to U.S. and Canadian Standards | U.L. Listed to U.S. and Canadian Standards | U.L. Listed to U.S. and Canadian Standards | U.L. Listed to U.S. and Canadian Standards |
Warranty | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years |
This transfer pump is built with a 1/3 horsepower motor and designed for high performance. The M-3260 is the 230-volt transfer pump of choice for heavy equipment applications.
Specifications | M-3260-ML | M-3260-AL | M-3260-PO |
---|---|---|---|
Design Type | Vane | Vane | Vane |
Voltage | 230 Volts AC | 230 Volts AC | 230 Volts AC |
Mechanical Connection | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing | 1 in. Inlet 1 in. Outlet 3/4 in. Bushing |
Flowrate | At 50 Hz: up to 64 LPM At 60 Hz: up to 76 LPM | At 50 Hz: up to 64 LPM At 60 Hz: up to 76 LPM | At 50 Hz: up to 64 LPM At 60 Hz: up to 76 LPM |
Hose | 12 ft 3.7 m 1 in. diameter | 12 ft 3.7 m 1 in. diameter | 12 ft 3.7 m 1 in. diameter |
Nozzle | Manual | Automatic | Nozzle not included |
Duty Cycle | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off | 30 minutes On / 30 minutes Off |
To Use With | Diesel fuel | Diesel fuel | Diesel fuel |
Approvals | U.L. Listed, CE | U.L. Listed, CE | U.L. Listed, CE |
Warranty | 2 years | 2 years | 2 years |
These are the pumps of choice for heavy construction, large farming and fleet operations. The 115-volt M-3130 provides the highest flow rate of any GPI transfer pump. The ¾ horsepower motor runs efficient and cool, extending pump life. The unique strainer and poppet design allows easy access and easy maintenance. Available with either manual or automatic nozzle. Comes with 12 ft of 1 in. UL grounded hose. Pump and Motor are UL Listed to U.S. and Canadian standards. Order the M-3295 for 230-volt models.
Specifications | M-3130-ML | M-3130-AD | M-3130-PO | M-3295-ML | M-3295-AL | M-3295-PO |
---|---|---|---|---|---|---|
Design Type | Vane | Vane | Vane | Vane | Vane | Vane |
Voltage | 115 or 230 Volts AC | 115 or 230 Volts AC | 115 or 230 Volts AC | 230 Volts AC | 230 Volts AC | 230 Volts AC |
Reads | Gallons - Litres | Gallons - Litres | Gallons - Litres | Gallons - Litres | Gallons - Litres | Gallons - Litres |
Mechanical Connection | 1 1/4 in. Inlet 1 in. Outlet | 1 1/4 in. Inlet 1 in. Outlet | 1 1/4 in. Inlet 1 in. Outlet | 1 1/4 in. Inlet 1 in. Outlet 2 in. Bung | 1 1/4 in. Inlet 1 in. Outlet 2 in. Bung | 1 1/4 in. Inlet 1 in. Outlet 2 in. Bung |
Fitting | NPT | NPT | N/A | BSPP | BSPP | BSPP |
Flowrate | Up to 30 GPM Up to 114 LPM | Up to 30 GPM Up to 114 LPM | Up to 30 GPM Up to 114 LPM | At 50 Hz: up to 95 LPM At 60 Hz: up to 113.5 LPM | At 50 Hz: up to 95 LPM At 60 Hz: up to 113.5 LPM | At 50 Hz: up to 95 LPM At 60 Hz: up to 113.5 LPM |
Nozzle | Manual | Automatic | Pump Only | Manual | Automatic | Pump Only |
Motor Protection | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device | Internal temperature-limiting device |
Warranty | 2 Years | 2 Years | 2 Years | 2 Years | 2 Years | 2 Years |